Items |
42703810 SNTL150P1205CDLA Model Sentinel 150P Programmable Switch Mode Battery Charger Price $212.92
|
42703811 SNTL150P2405CDLA Model Sentinel 150P Programmable Switch Mode Battery Charger Price $262.61
|
42703820 SNTL150P1205CDALA Model Sentinel 150P Programmable Switch Mode Battery Charger Price $236.52
|
42703821 SNTL150P2405CDALA Model Sentinel 150P Programmable Switch Mode Battery Charger Price $262.21
|
42703825 S150P PC SUITE Price $207.91
|
|||||
Description | N/A Sentinel 150P, 12 V/5 A nominal output. | N/A Sentinel 150P, 24 V/5 A nominal output. | N/A As 42.70.3810, plus alarm output and control input (programmable functions). | N/A As 42.70.3811, plus alarm output and control input (programmable functions). | N/A PC SUITE CD DISCK AND USB TO 7 PIN CONNECTOR ON S150P SERIES ONLY. | |||||
Model Number | N/A SNTL150P1205CDLA | N/A SNTL150P2405CDLA | N/A SNTL150P1205CDALA | N/A SNTL150P2405CDALA | N/A | |||||
Alternate Current (AC) Operating Voltage | N/A 95 to 265 V | N/A 95 to 265 V | N/A 95 to 265 V | N/A 95 to 265 V | N/A | |||||
Operating Frequency | N/A 47 to 63 Hz | N/A 47 to 63 Hz | N/A 47 to 63 Hz | N/A 47 to 63 Hz | N/A | |||||
Direct Current (DC) Nominal Voltage | N/A 12 V | N/A 24 V | N/A 12 V | N/A 24 V | N/A | |||||
Maximum Current Limit | N/A 5 A | N/A 5 A | N/A 5 A | N/A 5 A | N/A | |||||
Voltage Ripple | N/A <1 % | N/A <1 % | N/A <1 % | N/A <1 % | N/A | |||||
Line Regulation | N/A <2 % | N/A <2 % | N/A <2 % | N/A <2 % | N/A | |||||
Load Regulation | N/A <2 % | N/A <2 % | N/A <2 % | N/A <2 % | N/A | |||||
Control Input | N/A Close to -DC to Activate Digital (Switch) Input Programmable Function | N/A Close to -DC to Activate Digital (Switch) Input Programmable Function | N/A Close to -DC to Activate Digital (Switch) Input Programmable Function | N/A Close to -DC to Activate Digital (Switch) Input Programmable Function | N/A | |||||
Alarm Output | N/A Programmable Function Relay Switched +DC | N/A Programmable Function Relay Switched +DC | N/A Programmable Function Relay Switched +DC | N/A Programmable Function Relay Switched +DC | N/A | |||||
Maximum Current Rating at 30 Direct Current (DC) Voltage (Alarm Output) | N/A 1 A | N/A 1 A | N/A 1 A | N/A 1 A | N/A | |||||
Protective Cover Material | N/A 1050 Aluminum | N/A 1050 Aluminum | N/A 1050 Aluminum | N/A 1050 Aluminum | N/A | |||||
Protective Cover Thickness | N/A 1.2 mm | N/A 1.2 mm | N/A 1.2 mm | N/A 1.2 mm | N/A | |||||
Operating Temperature | N/A -30 to 60 ºC-22 to 140 ºF | N/A -30 to 60 ºC-22 to 140 ºF | N/A -30 to 60 ºC-22 to 140 ºF | N/A -30 to 60 ºC-22 to 140 ºF | N/A | |||||
Storage Temperature | N/A -40 to 60 ºC-40 to 140 ºF | N/A -40 to 60 ºC-40 to 140 ºF | N/A -40 to 60 ºC-40 to 140 ºF | N/A -40 to 60 ºC-40 to 140 ºF | N/A | |||||
Relative Humidity | N/A 20 to 90 % | N/A 20 to 90 % | N/A 20 to 90 % | N/A 20 to 90 % | N/A | |||||
Electrical Safety | N/A 2006/95/EC (EN 60065) | N/A 2006/95/EC (EN 60065) | N/A 2006/95/EC (EN 60065) | N/A 2006/95/EC (EN 60065) | N/A | |||||
Electromagnetic Compatibility | N/A 2004/108/EC (EN 61000-6-2, EN 61000-6-4) | N/A 2004/108/EC (EN 61000-6-2, EN 61000-6-4) | N/A 2004/108/EC (EN 61000-6-2, EN 61000-6-4) | N/A 2004/108/EC (EN 61000-6-2, EN 61000-6-4) | N/A | |||||
Overall Width (W) | N/A 4.28 in108.6 mm | N/A 4.28 in108.6 mm | N/A 4.28 in108.6 mm | N/A 4.28 in108.6 mm | N/A | |||||
Overall Height (H) | N/A 5.31 in135 mm | N/A 5.31 in135 mm | N/A 5.31 in135 mm | N/A 5.31 in135 mm | N/A | |||||
Overall Depth (D) | N/A 1.77 in45 mm | N/A 2.17 in55 mm | N/A 1.77 in45 mm | N/A 2.17 in55 mm | N/A | |||||
Fixing Holes (X) | N/A 3.90 in99 mm | N/A 3.90 in99 mm | N/A 3.90 in99 mm | N/A 3.90 in99 mm | N/A | |||||
Fixing Holes Diameter (F) | N/A 0.22 in5.65 mm | N/A 0.22 in5.65 mm | N/A 0.22 in5.65 mm | N/A 0.22 in5.65 mm | N/A | |||||
Weight | N/A 1.43 lb0.65 kg | N/A 1.65 lb0.75 kg | N/A 1.43 lb0.65 kg | N/A 1.65 lb0.75 kg | N/A .75 lb | |||||
Output Calibration Information | N/A Standard and custom output calibrations are selected using the SNTL150P-PCSUITE software tool. Calibration figures shown below are at 20 ºC. If temperature compensation is enabled, and remote SNTL-RTC temperature sensor connected, output voltage automatically varies by 3 mV per cell per 1 ºC deviation from 20 ºC, within the range -10 to +50 ºC. Increasing temperatures give decreasing outputs; decreasing temperatures give increasing outputs. | N/A Standard and custom output calibrations are selected using the SNTL150P-PCSUITE software tool. Calibration figures shown below are at 20 ºC. If temperature compensation is enabled, and remote SNTL-RTC temperature sensor connected, output voltage automatically varies by 3 mV per cell per 1 ºC deviation from 20 ºC, within the range -10 to +50 ºC. Increasing temperatures give decreasing outputs; decreasing temperatures give increasing outputs. | N/A Standard and custom output calibrations are selected using the SNTL150P-PCSUITE software tool. Calibration figures shown below are at 20 ºC. If temperature compensation is enabled, and remote SNTL-RTC temperature sensor connected, output voltage automatically varies by 3 mV per cell per 1 ºC deviation from 20 ºC, within the range -10 to +50 ºC. Increasing temperatures give decreasing outputs; decreasing temperatures give increasing outputs. | N/A Standard and custom output calibrations are selected using the SNTL150P-PCSUITE software tool. Calibration figures shown below are at 20 ºC. If temperature compensation is enabled, and remote SNTL-RTC temperature sensor connected, output voltage automatically varies by 3 mV per cell per 1 ºC deviation from 20 ºC, within the range -10 to +50 ºC. Increasing temperatures give decreasing outputs; decreasing temperatures give increasing outputs. | N/A | |||||
Output Calibration Specification Table |
N/A
Output Calibration Specification Table for Sentinel 150P Programmable Switch Mode Battery Chargers |
N/A
Output Calibration Specification Table for Sentinel 150P Programmable Switch Mode Battery Chargers |
N/A
Output Calibration Specification Table for Sentinel 150P Programmable Switch Mode Battery Chargers |
N/A
Output Calibration Specification Table for Sentinel 150P Programmable Switch Mode Battery Chargers |
N/A
|
|||||
Electrical Connections |
N/A
Electrical Connections for Sentinel 150P Programmable Switch Mode Chargers |
N/A
Electrical Connections for Sentinel 150P Programmable Switch Mode Chargers |
N/A
Electrical Connections for Sentinel 150P Programmable Switch Mode Chargers |
N/A
Electrical Connections for Sentinel 150P Programmable Switch Mode Chargers |
N/A
|
|||||
Features |
N/A
|
N/A
|
N/A
|
N/A
|
N/A | |||||
AutoBoost | N/A AutoBoost provides a temporary increase in output voltage, equalizing the charge between cells and maximizing battery life and capacity. AutoBoost is triggered automatically when the battery falls below a preset voltage, and reverts to float mode automatically at the end of the boost cycle, preventing battery over-charge and gassing. | N/A The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. Sentinel can be configured to sense battery temperature from a remote sensor and automatically compensate the output charge voltage. | N/A AutoBoost provides a temporary increase in output voltage, equalizing the charge between cells and maximizing battery life and capacity. AutoBoost is triggered automatically when the battery falls below a preset voltage, and reverts to float mode automatically at the end of the boost cycle, preventing battery over-charge and gassing. | N/A A' option models include a control input and alarm output, both with configurable functions. The input can be configured for use with panel relay circuits or operator switches, giving additional control over the output, e.g. AutoBoost initiation and termination. The alarm relay output can be configured to operate during a one or more (up to 7) fault conditions: mains fail, DC connection error, battery missing, temp sensor short, low battery volts, high battery volts, charge fail. | N/A | |||||
Alarm Output and Control Input ('A' Option) | N/A A' option models include a control input and alarm output, both with configurable functions. The input can be configured for use with panel relay circuits or operator switches, giving additional control over the output, e.g. AutoBoost initiation and termination. The alarm relay output can be configured to operate during a one or more (up to 7) fault conditions: mains fail, DC connection error, battery missing, temp sensor short, low battery volts, high battery volts, charge fail. | N/A The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. Sentinel can be configured to sense battery temperature from a remote sensor and automatically compensate the output charge voltage. | N/A The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. Sentinel can be configured to sense battery temperature from a remote sensor and automatically compensate the output charge voltage. | N/A A' option models include a control input and alarm output, both with configurable functions. The input can be configured for use with panel relay circuits or operator switches, giving additional control over the output, e.g. AutoBoost initiation and termination. The alarm relay output can be configured to operate during a one or more (up to 7) fault conditions: mains fail, DC connection error, battery missing, temp sensor short, low battery volts, high battery volts, charge fail. | N/A | |||||
Temperature Compensation | N/A The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. Sentinel can be configured to sense battery temperature from a remote sensor and automatically compensate the output charge voltage. | N/A The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. Sentinel can be configured to sense battery temperature from a remote sensor and automatically compensate the output charge voltage. | N/A The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. Sentinel can be configured to sense battery temperature from a remote sensor and automatically compensate the output charge voltage. | N/A The optimum charge voltage for lead acid and NiCd batteries varies with ambient temperature. Sentinel can be configured to sense battery temperature from a remote sensor and automatically compensate the output charge voltage. | N/A | |||||
Versatile | N/A The Sentinel 150P uses an open circuit board construction with an aluminum protective cover, for surface mounting in an existing control panel. Electrical connection is by quick-connect, two-part type terminal blocks. | N/A The Sentinel 150P uses an open circuit board construction with an aluminum protective cover, for surface mounting in an existing control panel. Electrical connection is by quick-connect, two-part type terminal blocks. | N/A Sentinel 150P can be configured and monitored using a PC-based software tool, model SNTL150P-PCSUITE. The tool offers a number of standard 'profiles' for different battery types, but also allows OEM-customization of all parameters for fine control in any application. The tool also enables real time monitoring and metrics for both charger and battery. |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A | |||||
Installation and Connection | N/A The Sentinel 150P uses an open circuit board construction with an aluminum protective cover, for surface mounting in an existing control panel. Electrical connection is by quick-connect, two-part type terminal blocks. |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A | |||||
Accessories |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A
Stock Code - 42.70.3619 Description - RTC sensor for remote temperature compensation feature, complete with 3 m/9.8 ft lead assembly. Non-standard lengths available to special order. Stock Code - 42.70.3825 Description - SNTL150P-PCCONN programming kit. Includes SNTL150P-PCSUITE software tool (PC compatible), USB-TTL interface and power/data connection leads. |
N/A | |||||
Warranty |
N/A
All part numbers are supplied with output calibrated for vented lead-acid cells. Output calibration can be optimized for different battery types by using the SNTL150P-PCSUITE software tool. Dimensions for reference only. Use actual product for mounting template. For safe heat dissipation, mount product in orientation shown, with minimum air-gap clearance of 40 mm/1.5 in. above/below and 25 mm/1.0 in. at each side. |
N/A A two year limited warranty on materials and workmanship is given with this product, details available on request. |
N/A
All part numbers are supplied with output calibrated for vented lead-acid cells. Output calibration can be optimized for different battery types by using the SNTL150P-PCSUITE software tool. Dimensions for reference only. Use actual product for mounting template. For safe heat dissipation, mount product in orientation shown, with minimum air-gap clearance of 40 mm/1.5 in. above/below and 25 mm/1.0 in. at each side. |
N/A
All part numbers are supplied with output calibrated for vented lead-acid cells. Output calibration can be optimized for different battery types by using the SNTL150P-PCSUITE software tool. Dimensions for reference only. Use actual product for mounting template. For safe heat dissipation, mount product in orientation shown, with minimum air-gap clearance of 40 mm/1.5 in. above/below and 25 mm/1.0 in. at each side. |
N/A | |||||
Note |
N/A
All part numbers are supplied with output calibrated for vented lead-acid cells. Output calibration can be optimized for different battery types by using the SNTL150P-PCSUITE software tool. Dimensions for reference only. Use actual product for mounting template. For safe heat dissipation, mount product in orientation shown, with minimum air-gap clearance of 40 mm/1.5 in. above/below and 25 mm/1.0 in. at each side. |
N/A
All part numbers are supplied with output calibrated for vented lead-acid cells. Output calibration can be optimized for different battery types by using the SNTL150P-PCSUITE software tool. Dimensions for reference only. Use actual product for mounting template. For safe heat dissipation, mount product in orientation shown, with minimum air-gap clearance of 40 mm/1.5 in. above/below and 25 mm/1.0 in. at each side. |
N/A
All part numbers are supplied with output calibrated for vented lead-acid cells. Output calibration can be optimized for different battery types by using the SNTL150P-PCSUITE software tool. Dimensions for reference only. Use actual product for mounting template. For safe heat dissipation, mount product in orientation shown, with minimum air-gap clearance of 40 mm/1.5 in. above/below and 25 mm/1.0 in. at each side. |
N/A
All part numbers are supplied with output calibrated for vented lead-acid cells. Output calibration can be optimized for different battery types by using the SNTL150P-PCSUITE software tool. Dimensions for reference only. Use actual product for mounting template. For safe heat dissipation, mount product in orientation shown, with minimum air-gap clearance of 40 mm/1.5 in. above/below and 25 mm/1.0 in. at each side. |
N/A | |||||
|